Power : Power By measuring circuit
Adjustable : over-and undervoltage threshold
function : over- under voltage
voltage : dc 12v
GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD
Overvoltage refers to the phenomenon that the rms value of the AC voltage rises at the power frequency, exceeding 10% of the rated value, and the long-term voltage fluctuation is longer than 1 minute. The occurrence of overvoltage is usually the result of load switching, for example: Cut off a large capacity load or energize the capacitor bank (overvoltage caused by excess reactive power compensation).
The abnormal voltage rise of the power system exceeding the working voltage under certain conditions belongs to an electromagnetic disturbance phenomenon in the power system. The insulation of electrical equipment is tolerant to the operating voltage for a long time, and must also withstand a certain range of overvoltage, so as to ensure the safe and reliable operation of the power system. Studying the causes of various overvoltages, predicting their amplitudes, and taking measures to limit them is a prerequisite for determining the insulation coordination of power systems, and is of great significance for the manufacture of electrical equipment and the operation of power systems.
Features:
Protective Functions
Applications
Model | DVRD | |||||||||||||||
Input circiut =measuring circuit | DC supply | |||||||||||||||
Rated voltage | DC12V.DC24V.DC36V,DC48V | |||||||||||||||
Monitoring functions | Overvoltage,undervoltage | |||||||||||||||
Voltage setting range |
| |||||||||||||||
Tripping delay time | 0.1~15s adjustable | |||||||||||||||
Voltage hysteresis | 3-5% fixed | |||||||||||||||
Reset delay time | 100ms | |||||||||||||||
indicators | normal,trip | |||||||||||||||
Output contacts | 2C/O | |||||||||||||||
Contact capacity | 6A,250VAC/30VDC(resistive load) | |||||||||||||||
Degree of protection | IP20 | |||||||||||||||
Working conditions | -25℃~65℃,≤85%RH,non-condensing | |||||||||||||||
Mechanical durability | 1000000 cycles | |||||||||||||||
Dielectric strength | >2KVAC 1min | |||||||||||||||
Weight | 130g | |||||||||||||||
Dimension(HXWXD) | 79X23X79mm | |||||||||||||||
Mounting | Din rail |
![]() |