Sign In | Join Free | My tjskl.org.cn
China Wenzhou Ginri Power Automation Co., Ltd. logo
Wenzhou Ginri Power Automation Co., Ltd.
Wenzhou Ginri Power Automation Co., Ltd.
Active Member

8 Years

Home > Single Phase Voltage Monitoring Relay >

Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay

Wenzhou Ginri Power Automation Co., Ltd.
Contact Now

Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay

  • 1
  • 2

Brand Name : GINR

Model Number : SVR1000/AD220

Certification : CE,CCC

Place of Origin : China

MOQ : 20 Pcs

Payment Terms : L/C, T/T, Western Union,Paypal

Supply Ability : 20000Pcs per month

Delivery Time : 1-30 days upon order quantity

Packaging Details : Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.

Rated voltage : AC/DC110-240V,50/60Hz

Monitoring functions : overvolatege, undervoltage

Delay time for overvoltage and undervoltage : 0.1-999s adjustable

Overvoltage setting range : AC/dc50.0-300v,5adjustbale

Output contactly : 1 CO& 1NC

Indicators : LCD indicating voltage,operationand fault status

Contact Now

Air-conditioning Single Phase Voltage Monitoring Relay DIN RAIL Mount

Abrupt changes in the state of the circuit and the electromagnetic state in the power system are the root cause of overvoltage generation. Overvoltage is divided into two categories of external overvoltage and internal overvoltage. Studying the causes of various overvoltages in power systems, predicting their amplitudes, and taking measures to limit them are prerequisites for determining the insulation coordination of power systems, and are of great significance for the manufacture of electrical equipment and the operation of power systems.
Regardless of the external overvoltage or internal overvoltage, it is affected by many random factors. It is necessary to combine the specific conditions of the power system, obtain data through various methods such as calculation, simulation and field measurement, and use probabilistic statistical methods to predict overvoltage.
For the cause of over-voltage, the power system must take protective measures to limit the over-voltage amplitude. Such as the installation of lightning protection lines, lightning arresters, reactors, switch contacts plus parallel resistance, etc., in order to reasonably implement insulation coordination to ensure the safe operation of the power system.

The overvoltage protector is a new type of overvoltage protector, which is mainly used to protect the insulation of generators, transformers, vacuum switches, busbars, motors and other electrical equipment from overvoltage damage.

♦ Features
-- Powered by the measuring circuit
-- Compatible with AC and DC supply
-- Built-in LCD and keypad afford a precise,digital setting
-- Compact modular 43mm housing
-- Adjustable over- and undervoltage threshold
-- Independent adjustable delay time for overvoltage, undervoltage
-- Adjustable reset mode:automatic reset or manual reset
-- 1 CO & 1NC contacts
-- Fault recording with last 3 faults

♦ Protective Functions
-- Overvoltage -- Undervoltage

♦ Typical Applications
• Pumps • Fans • Air-conditioning system
• Blowers • Motors • Compressors • Elevators

Approvals
• CE • CCC

♦ Technical data

ModelSVR1000/AD220
Measuring circuitA1+,A2-
Rated voltageAC/DC110-240V,50/60Hz
Monitoring functionsovervoltage,undervoltage
Overvoltage setting rangeAC/dc50.0-300v,5adjustbale
Undervoltage setting rangeAC/DC50.0-300V adjustable
Voltage hysteresis1.0-90.0V adjustable

Delay time for overvoltage
and undervoltage

0.1-999s adjustable

Rest modeManual/automatic/automatic with power on delay
Delay time for rest 0.1-999s adjustable
IndicatorsLCD indicating voltage,operationand fault satatu
Output contactly1 CO& 1NC
Contact capacity6A,250VAC
Dimensions(H*W*D)80*43*54mm
Mounting DIN rail


Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay


































Product Tags:

single phase undervoltage relay

      

single phase failure relay

      
Quality Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay for sale

Air - conditioning Single Phase Protection Relay , AC DC Under Voltage Monitoring Relay Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wenzhou Ginri Power Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)